    Description

      Liveness probe in business central image is unable to detect crashed business central. It checks only that EAP is working but it is unable to detect that business central application is broken.

      To reproduce this bug run business central in Openshift and manually undeploy war with business central. Then Openshift should replace the pod with business central with new one. However, it does not happen because liveness probe is unable to detect that business central is not running.