Uploaded image for project: 'Tools (JBoss Tools)'
  1. Tools (JBoss Tools)
  2. JBIDE-12033

New Seam Project Wizard - when AS7 runtime is set, seam config is not set properly after changing to EAP5.1.2 runtime

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Major Major
    • 4.0.0.Alpha1
    • 3.3.0.CR1
    • seam2
    • None

      I guess this is not really so urgent, so targeting for 3.3.1.

      While verifying JBIDE-11815, I noticed the following:
      When you open the New Seam Project Wizard and select AS7/EAP6 runtime, both Dynamic web module and Configuration are set properly, to 3.0 and Dynamic Web Project with Seam 2.3, respectively.
      But when you then change the runtime to EAP 5.1.2 the web module version is not changed (it stays empty) and the Configuration is set to <custom>. Even if set the web module to 2.5, Configuration is not set to Seam 2.2.

      I would expect that after changing runtime to EAP 5.1, both web module version and configuration would be changed accordingly.

            alexeykazakov Alexey Kazakov
            exd-mmalina Martin Malina
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

              Created:
              Updated:
              Resolved: