Access log rotation may rotate logs at noon rather than midnight

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Major Major
    • 7.1.0.DR8
    • None
    • Undertow
    • None

      When calculating the rotation time for log files the constant Calendar.HOUR is used to set the hour to 0 for midnight. It should use the Calendar.HOUR_OF_DAY or set the AM_PM value as well.

      public static final int HOUR
      

      Field number for get and set indicating the hour of the morning or afternoon. HOUR is used for the 12-hour clock (0 - 11). Noon and midnight are represented by 0, not by 12. E.g., at 10:04:15.250 PM the HOUR is 10.

      public static final int HOUR_OF_DAY
      

      Field number for get and set indicating the hour of the day. HOUR_OF_DAY is used for the 24-hour clock. E.g., at 10:04:15.250 PM the HOUR_OF_DAY is 22.
      See Also:
      HOUR, Constant Field Values

            jperkins-rhn James Perkins