Unable to access the web console when the master node is in passive mode

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Unresolved
    • Icon: Undefined Undefined
    • None
    • AMQ 7.11.1.GA
    • console
    • False
    • None
    • False
    • Moderate

      The web console in the master node cannot be accessed should that become the passive node in the event of a failover. However, the web console can be accessed when the slave node is in passive mode.

      The embedded web server will not get initialised when the master node becomes the passive broker instance following a failover event. (allow-failback must be set to false in the slave instance.) 

      t1. Master - Live: web console can be accessed
      t2. Slave - Backup: web console can be accessed
      t3. Kill the master broker 
      t4. Start the master broker
      t5. The master broker becomes passive: Unable to access the web console