Details
-
Story
-
Resolution: Done
-
Major
-
JBoss A-MQ 6.3
-
None
Description
producer flow control info log only appears the first time PFC kicks in for a destination.
In the code warnOnProducerFlowControl is set to false first time and I cannot find it reset anywhere https://github.com/jboss-fuse/activemq/blob/dcd07a06dea0c0857f6649e40a2d1cb946c458a4/activemq-broker/src/main/java/org/apache/activemq/broker/region/Queue.java#L634-634
Would be good to have this logged periodically (maybe on a 1 or 5 minutes interval) in the logs so that tools (or people) monitoring the log files could be aware of the ongoing issue.
Attachments
Issue Links
- is related to
-
ENTMQ-2064 [A-MQ6, Producer Flow Control] JMX Queue attribute blockedsends not updated when sending message "sync send".
- Closed