Compatibility problem: allow a timeout value of "0" to be set

    XMLWordPrintable

Details

    • Bug
    • Resolution: Done
    • Major
    • 14.0.0.Beta2
    • None
    • Transactions
    • None

    Description

      Previously we allowed a transaction timeout value of "0" to be set in the transaction subsystem, meaning "no transaction timeout". After the WF 11 changes, we've stopped allowing that value to be set. This behavior should be restored, with "0" translating into some "very large" value.

      The transaction team has indicated that using Integer.MAX_VALUE has historically exhibited problems, so a different, smaller-but-still-large value should be used in this case.