Uploaded image for project: 'Weld'
  1. Weld
  2. WELD-2393

Order of Portable Extension Events inconsistent with specification

    Details

    • Type: Bug
    • Status: Resolved (View Workflow)
    • Priority: Major
    • Resolution: Done
    • Affects Version/s: 3.0.0.Final
    • Fix Version/s: 2.4.4.Final, 3.0.1.Final
    • Component/s: None
    • Labels:
      None
    • Steps to Reproduce:
      Hide

      example source attached demonstrates problem.

      Show
      example source attached demonstrates problem.

      Description

      According to cdi-spec Bean Discovery, for each producer of each enabled bean, the container must
      1. fire an event of type ProcessInjectionPoint for each injection point
      2. fire an event of type ProcessProducer
      3. ProcessBeanAttributes
      4. ProcessBean

      However, the ProcessProducer event is happening after the ProcessBeanAttributes events.

        Gliffy Diagrams

          Attachments

            Activity

              People

              • Assignee:
                manovotn Matej Novotny
                Reporter:
                chas_honton Charles Honton
              • Votes:
                0 Vote for this issue
                Watchers:
                3 Start watching this issue

                Dates

                • Created:
                  Updated:
                  Resolved: