BeanDeploymentModules fallback not entirely correct

    Details

    • Type: Bug
    • Status: Resolved (View Workflow)
    • Priority: Major
    • Resolution: Done
    • Affects Version/s: 2.4.3.Final, 3.0.0.Final
    • Fix Version/s: 2.4.4.Final, 3.0.1.Final
    • Component/s: None
    • Labels:
      None

      Description

      BeanDeploymentModules, if registered, returns a fallback "default" BeanDeploymentModule (whose isWebModule() returns false) for a bean archive which does not have a EEModuleDescriptor. As a result @Initialized(ApplicationScoped.class) event is fired twice for a WAR without EEModuleDescriptor. Once from HttpContextLifecycle and then also from WeldStartup. The same applies to @Destroyed(ApplicationScoped.class).