Uploaded image for project: 'Teiid'
  1. Teiid
  2. TEIID-5174

Filter internal constructs from oracle metadata

    Details

      Description

      Even with the import table types set to TABLE, an Oracle Database 12c Enterprise Edition Release 12.2.0.1.0 accessed with the 12.1.0.1.0 driver will contain internal tables which will cause the deployment to error:

      TEIID31071 Invalid table; Table oracleModel.HS_PARTITION_COL_NAME has no columns defined

      It would be good if these were filtered by default. The workaround is to specify a schema or regex to prevent such tables from being imported.

        Gliffy Diagrams

          Attachments

            Activity

              People

              • Assignee:
                shawkins Steven Hawkins
                Reporter:
                shawkins Steven Hawkins
              • Votes:
                0 Vote for this issue
                Watchers:
                2 Start watching this issue

                Dates

                • Created:
                  Updated:
                  Resolved: