Osisoft translator - MOD fails with non-integer arguments

    Details

      Description

      Query such as

      SELECT FloatNum, 11, MOD(FloatNum, 11) FROM BQT1.SmallA
      

      fails on the PI server with

      com.osisoft.rdsa.RdsaException: [PIOLEDBENT] [SQL Analyzer] [Line 1:34] [%] Overload resolution failed for (Single, Single) argument(s).
      

      Similarly for Double arguments. It appears that the modulo operator % is only defined when both arguments are integers (contrary to PI OLEDB Enterprise 2016 User Guide, which states that it is defined for all numeric data types)