Uploaded image for project: 'FUSE Message Broker'
  1. FUSE Message Broker
  2. MB-812

Can only have one duplex networkConnection per transportConnection

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Major
    • Resolution: Done
    • Affects Version/s: 5.4.2-fuse-00-00
    • Fix Version/s: 5.4.2-fuse-02-00
    • Component/s: None
    • Labels:
      None
    • Similar Issues:
      Show 9 results 

      Description

      AMQ-2774 introduced an unintended restriction on the number of duplex networkConnections that can be made to the same port on a remote broker.
      You now need a transportConnector per networkConnector.

        Gliffy Diagrams

          Activity

          Hide
          garytully Gary Tully added a comment -

          merged to 5.4-fusesource

          Show
          garytully Gary Tully added a comment - merged to 5.4-fusesource

            People

            • Assignee:
              garytully Gary Tully
              Reporter:
              socallag Sean O'Callaghan
            • Votes:
              0 Vote for this issue
              Watchers:
              0 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: