SEQUENCER leaks sequence numbers

    XMLWordPrintable

Details

    • Bug
    • Resolution: Done
    • Major
    • 3.0.10, 3.1
    • 3.0.9, 3.1
    • None

    Description

      As noted in JGRP-1458, it looks as though SEQUENCER always thinks that sequence numbers must start at zero. But a member who joins a group after some messages have already been broadcast may never receive sequence number zero. So, I think, his SeqnoTable will grow indefinitely.

      Note that this one's mostly through code reading. I think I'm right; but I'm happy to be told otherwise!

      Pull request to follow shortly.