Uploaded image for project: 'Infinispan'
  1. Infinispan
  2. ISPN-8797

Administration console - Counters tab - reset counter operation: doesn't work

    XMLWordPrintable

Details

    • Bug
    • Resolution: Done
    • Major
    • 9.2.0.Final
    • 9.2.0.CR2
    • Console
    • None
    • Hide

      1. Create counter.
      2. Increase or decrease it's value (e.g. via CLI)
      3. Refresh and check 'Current value' field
      3. Click 'Reset'
      4. Confirm
      5. Refresh and check 'Current value' field - it hasn't changed.
      Expected:
      Current value reverted to initial counter value

      Show
      1. Create counter. 2. Increase or decrease it's value (e.g. via CLI) 3. Refresh and check 'Current value' field 3. Click 'Reset' 4. Confirm 5. Refresh and check 'Current value' field - it hasn't changed. Expected: Current value reverted to initial counter value

    Description

      Reset counter button doesn't work. No errors shown.

      Attachments

        Issue Links

          Activity

            People

              vblagoje Vladimir Blagojevic (Inactive)
              vblagoje Vladimir Blagojevic (Inactive)
              Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: