  2. ISPN-10264

Wrong time conversion for async xsite take-offline

    XMLWordPrintable

Details

    Description

      The XSiteAsyncAckListener is notified with the send-timestamp in nanoseconds and it must be converted to milliseconds to compute the take-offline status.