GTID set is not properly initialized after DB failover

    XMLWordPrintable

Details

    • Bug
    • Resolution: Done
    • Critical
    • 0.9.0.Beta2
    • 0.9.0.Beta1
    • mysql-connector
    • None

    Description

      Let's suppose there are two MySQL databases in master/master setup with HA proxy in front of it
      1) Debezium is connected to database 1
      2) Events are processed form database
      3) Database 1 is shutdown
      4) New records are added to database 2
      4) Debezium is connected to database 2
      5) Database 2 reports a GTID set of GTIDs coming from database 1 and its own GTIDs
      6) Debezium fiters out Database 2 GTIDs because io.debezium.connector.mysql.MySqlTaskContext.filterGtidSet(GtidSet, GtidSet) does not remove database 2 UUIDs from filtered set as it does not have any recorded to overwrite
      7) All records that were written before Debezium restart are lost