Uploaded image for project: 'Application Server 7'
  1. Application Server 7
  2. AS7-245

Bug in ProcessManager stream processing when read word == '0'

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Won't Do
    • Icon: Major Major
    • 7.0.0.CR1
    • None
    • Domain Management
    • None

      The way I discovered this bug was to configure a server JVM element with no environment properties. This will cause the addProcess parsing to fail on the process manager side. Since it will go to read the number of environment entires and it will come back as '0' which will be read as a "MORE" status instead of actually being the value of the word.

            johnbailey_jira John Bailey (Inactive)
            johnbailey_jira John Bailey (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            0 Start watching this issue

              Created:
              Updated:
              Resolved: